Models in this series
LG's manuals for this series cover these models. Your model number is on the rating label — where to find it.
- DLE1101W
- DLG1102W
LG DLE1101W error codes
These 9 error codes appear in LG's documentation for this series. The page reference points to the LG manual where the code is listed. If your code is not here, check the full list of LG dryer codes.
| Code | What it means | What you can do | LG source |
|---|---|---|---|
| d95 | Exhaust duct about 95% restricted | Do not use the dryer. Clean or repair the vent; check for crushed flex duct behind the dryer and a stuck outside flap. | LG owner's manual (DLE1101W), p. 35 |
| dE | Door not closed — door switch open | Close the door firmly; if it persists the door switch has failed. | LG service manual (DLE1101W), p. 23 |
| E5 | Steam pump error (test mode) | Pump or harness; call for repair. | LG service manual (DLE1101W), p. 19 |
| HS | Humidity sensor error — or Flow Sense test run while the dryer was still warm meaning varies by model | Run the installation check / Flow Sense test only when the dryer is cold. If HS returns cold, the sensor needs service. | LG service manual (DLE1101W), p. 17 |
| nP | Supply voltage not correct or power was interrupted | Make sure the breaker is fully on (electric dryers use a double 240 V breaker) and the plug is seated. If the code returns, have an electrician check the outlet. | LG service manual (DLE1101W), p. 17 |
| PF | Supply voltage not correct or power was interrupted | Make sure the breaker is fully on (electric dryers use a double 240 V breaker) and the plug is seated. If the code returns, have an electrician check the outlet. | LG service manual (DLE1101W), p. 17 |
| PS | Supply voltage not correct or power was interrupted | Make sure the breaker is fully on (electric dryers use a double 240 V breaker) and the plug is seated. If the code returns, have an electrician check the outlet. | LG service manual (DLE1101W), p. 17 |
| tE1 | Thermistor error — open or shorted sensor, or large difference between real and sensed temperature | Thermistor or harness; call for repair. | LG owner's manual (DLE1101W), p. 28 |
| tE2 | Thermistor out of range (meaning differs on heat pump models) meaning varies by model | Very cold air from a long vent can trigger it on standard models; otherwise a sensor fault. | LG owner's manual (DLE1101W), p. 28 |
When to call a technician
Codes that point to a sensor, motor, fan, board, heater or the sealed system need testing with meters and LG test mode. Typical LG dryer repairs in Las Vegas cost $200–$530 including the $75 service call — see repair prices and LG dryer repair.
Step-by-step guides for common problems:
Sources
- LG service manual for DLE1101W, DLG1102W — 40 pages, LG P/No MFL62119948
- LG owner's manual for DLE1101W — 80 pages
- LG owner's manual for DLE1101W, DLG1102W — 80 pages
Facts on this page are taken from LG's own documentation and LG's technician error-code reference; explanations are written by our technicians. LG manuals are copyrighted by LG Electronics and are not reproduced here. LG Appliances Repair Service is independent and not affiliated with LG.
LG DLE1101W questions
What does d95 mean on an LG DLE1101W?
Exhaust duct about 95% restricted. Do not use the dryer. Clean or repair the vent; check for crushed flex duct behind the dryer and a stuck outside flap.
What does tE1 mean on an LG DLE1101W?
Thermistor error — open or shorted sensor, or large difference between real and sensed temperature. Thermistor or harness; call for repair.
Do you repair the LG DLE1101W in Las Vegas and Henderson?
Yes. LG Appliances Repair Service repairs LG dryers, including the DLE1101 series, in homes across Las Vegas and Henderson. The $75 service call is credited toward the repair.