The LG dryer codes we see most in Las Vegas are d80–d95 (the exhaust vent is 80–95% restricted), tE1–tE3 (temperature sensor or heating problems), dE (door switch) and F0/IF (lint filter missing). A restricted vent is the most common root cause of no-heat and slow-drying complaints.

Reviewed by LG Appliances Repair Service technicians · Updated

Vent (Flow Sense) codes

CodeMeaningWhat to do
d80Exhaust duct about 80% restrictedClean the lint filter, the duct behind the dryer and the vent to the outside hood. The number is roughly the percentage of airflow blocked.
d85Exhaust duct about 85% restrictedSame as d80 — clean the full vent run. Long dry times are normal until you do.
d90Exhaust duct about 90% restrictedStop using the dryer until the vent is cleaned. Severe restriction is a fire hazard.
d95Exhaust duct about 95% restrictedDo not use the dryer. Clean or repair the vent; check for crushed flex duct behind the dryer and a stuck outside flap.
HSHumidity sensor error — or Flow Sense test run while the dryer was still warmRun the installation check / Flow Sense test only when the dryer is cold. If HS returns cold, the sensor needs service.

Heat and temperature codes

CodeMeaningWhat to do
tE1Thermistor error — open or shorted sensor, or large difference between real and sensed temperatureThermistor or harness; call for repair.
tE2Thermistor out of range (meaning differs on heat pump models)Very cold air from a long vent can trigger it on standard models; otherwise a sensor fault.
tE3Thermistor out of range or too hot — heater not working because a thermostat tripped or voltage is abnormalOn electric models check the 240 V double breaker (one half tripped = drum turns, no heat). Clean the vent; then heater circuit, high-limit or element.
tE4Steam generator thermistor errorCall for repair.
tE5 – tE7Heat pump dryer thermistor errors (compressor inlet / outlet, evaporator inlet)Call for repair.
gAS / 9A5Gas dryer not heating — no temperature riseMake sure the gas valve behind the dryer is on. Then igniter, flame sensor or gas valve coils.
F1Drum temperature too high — not enough airflow (condensing / heat pump)Clean the lint filter; on condenser models remove and rinse the condenser.

Start, door and power codes

CodeMeaningWhat to do
dEDoor not closed — door switch openClose the door firmly; if it persists the door switch has failed.
dE2Door not locked (models with a door lock)Door lock switch or wiring.
F0Filter not insertedInstall the lint filter fully; if it is in place, the filter's magnet reed switch is at fault.
IFInstall filter — lint filter missingSame as F0.
PS / nP / PFSupply voltage not correct or power was interruptedCheck the outlet and breaker. Electric dryers need 240 V; condensing dryers show tE3 instantly on a 120 V circuit.
EEEEPROM (control memory) errorMain board replacement.
nE / nF / nC / nUWi-Fi / NFC module messages in test modeDrying is not affected.

Steam codes

CodeMeaningWhat to do
Add WaterSteam feeder is empty or drawer not closedFill the steam feeder to the MAX line with tap water (not distilled) and close the drawer.
E1Steam module overheating (above about 320 °F)Steam generator replacement.
E3No water supply for steamCheck the inlet hose and valve for the steam supply.
E4Steam heating — generator did not reach temperature in timeCheck the steam generator wiring; replace generator if needed.
E5Steam pump error (test mode)Pump or harness; call for repair.

Heat pump and condensing dryer codes

CodeMeaningWhat to do
AECompressor error (heat pump models)Call for repair.
LE1Tub/blower motor locked — often a dryer sheet in the blowerCall for repair.
LE2Drum motor low current (condensing) or compressor error (heat pump)Clean the lint filter; then call.
LE3Dry fan restarted three times without success (heat pump)Call for repair.
OE / DRN / E13Drain pump error — condensate water not droppingCheck the drain hose for kinks; clean lint from the pump.

Not error codes

CodeMeaningWhat to do
CLChild lock is onPress and hold the Child Lock button for 3 seconds.
big / bi9Steam Fresh large-load settingNormal.
UPThinQ feature update availableUpdate in the LG ThinQ app.

When to call

Clean the vent first for any d-code or slow drying. tE codes after a vent cleaning, gAS, dE that will not clear, and all heat pump codes need a technician. See LG dryer repair — $75 service call, credited toward the repair.

LG dryer error code questions

What does d90 mean on my LG dryer?

The exhaust vent is about 90% restricted. The dryer measured very low airflow through the duct. Clean the lint filter, the duct behind the dryer and the full vent run to the outside before using it again.

How do I clear the d80 code on an LG dryer?

Clean the vent, then run the installation check or Flow Sense test with a cold dryer. The code clears once the dryer measures normal airflow.

Why does my LG dryer show tE3?

The heater is not working because a thermostat tripped from overheating or the supply voltage is wrong. Check both halves of the 240 V breaker and clean the vent, then call if it returns.

Online booking

Code keeps coming back? Book a technician

Tell us what the appliance is doing and when you are home. We call back to confirm a time — usually the same day during business hours. The $75 service call is credited toward your repair.

  • EPA 608 certified
  • Fully insured
  • $75 service call, credited to repair
  • 90-day labor · 1-yr parts warranty

Request LG repair

Prefer to talk? Call (702) 707-5107. We confirm online requests during business hours.

LG appliances only · Las Vegas & Henderson

Your LG appliance, fixed by technicians who work on LG every day.

$75 service call, credited toward the repair. Written quote before any work. EPA 608 certified, fully insured. 90-day labor warranty, 1-year warranty on parts.

Call now Book online